Adjustable Pressure switch 901 Prescal®

Designed with adjustable switching pressure for Ex zones 0, 1, 2 and 21, 22

Adjustable pressure switch monitoring overpressure, vacuum or differential pressure of liquid and gaseous – also aggressive – media.

The pressure switch uses a scaled adjustment knob to adjust the trip and reset pressure without using a screwdriver.

Applications of the Adjustable Pressure switch 901 Ex Prescal

  • Wastewater technology
  • Liquid level measurement
  • Pump control
  • Medical technology

Technical Specifications of Adjustable Pressure switch 901 Ex Prescal

Medium

Air, (non-)combustible and aggressive gases and vapours

Temperature ranges:

Medium and ambient temperature: -20° C to +85° C
Storage temperature: -40° C to +85° C

Trip pressure ranges:

Overpressure:

5 to 20 mbar (min. measuring range)
7 to 12 bar (max. measuring range)

Vacuum:

-5 to -20 mbar (min. measuring range)
-300 to -700 mbar (max. measuring range)

Differential pressure:

5 to 20 mbar (min. measuring range)
10 to 50 mbar (max. measuring range)