Oxygen cleaning is a specialist degreasing and cleaning process that removes all traces of hydrocarbons, oils, greases and other contaminants from sensor components. It is required for sensors intended for use in oxygen-enriched or pure oxygen environments, where even minute hydrocarbon contamination can cause violent ignition or explosion.
The process is carried out to recognised industry standards such as ASTM G93 and ISO 15001, ensuring the sensor is safe for oxygen service from the point of manufacture. Once cleaned, the product must be handled and stored under controlled conditions to preserve its oxygen-clean integrity until installation.
Cleaned to recognised standards
ASTM G93ISO 15001
Safe for oxygen service from the point of manufacture, provided the handling and storage steps on this page are followed.
Section 2
WARNING: Do Not Contaminate This Product
Failure to observe the following precautions will compromise the oxygen-clean status of this product and may create a serious safety hazard:
Do NOT handle with bare hands. Skin oils will contaminate the oxygen-clean surface.
Do NOT place on dirty, greasy or standard workshop surfaces.
Do NOT use standard tools or fittings that have not been oxygen-cleaned or degreased.
Do NOT use lubricants, thread compounds or sealants unless specifically rated for oxygen service (e.g. PTFE tape approved for Oâ‚‚ service).
Re-contaminated sensors must not be used in oxygen service. Contact Stork Solutions immediately.
Section 3
Required PPE & Handling Equipment
Clean, powder-free nitrile or latex gloves (changed before handling if soiled).
Lint-free cleanroom wipes or cloths (no shedding fibres).
Clean, dedicated oxygen-service tools and fittings only.
Work on a clean, lint-free, degreased surface or cleanroom bench mat.
Handle the sensor from the body/housing only. Avoid contact with ports, threads and wetted parts where possible.
Section 4
Storage & Re-Sealing
The sensor is supplied in a sealed anti-static bag with an oxygen-clean environment.
Do not open the bag until immediately before installation.
If the sensor is not installed immediately after opening, re-seal in a clean, dedicated oxygen-service bag.
Store in a cool, dry location away from hydrocarbons, solvents, lubricants and contaminating materials.
Do not store loose in a toolbox or general storage area.
Retain original packaging until installation is confirmed.
Section 5
Installation Notes
Ensure all mating fittings, tubing and system components have also been oxygen-cleaned or are confirmed compatible with oxygen service.
Verify that thread sealant and any joining compounds are approved for oxygen service.
After installation, do not introduce hydrocarbons into the system.
Our team is available to advise on oxygen-cleaned sensor handling, installation, and compatibility. Do not hesitate to contact us before installation if you have any questions.
Stork Solutions Ltd, 6 Fortuna Court, Calleva Park, Aldermaston, RG7 8UB, United Kingdom
Document Ref: ECD-026Issue: 1September 2026Documents are subject to change without notice.
Sign Up For Our Newsletter!
Send through your product enquiry
Thank you for visiting Stork Solutions.
Please fill in the form and send through your enquiry. If you are interested in multiple products then please add the details into the message section.