Level Transmitters for Treatment Tank Level Measurement
Reliable treatment tank level measurement underpins every stage of a water or wastewater treatment works. Whether you are controlling flow into a balancing tank, holding the right volume in an aeration basin, or keeping a chemical store topped up, an accurate level signal keeps pumps, dosing and inventory under control and helps avoid overflows, dry-running and unplanned site visits.
Stork Solutions supplies hydrostatic level transmitters suited to the conditions inside treatment tanks, from screw-in transmitters for tank walls and pipework to submersible probes that hang directly in the liquid. Plastic-bodied probes cater for aggressive dosing chemicals, stainless steel versions handle general process duty, and 4–20 mA outputs (with HART® on selected models) connect straight into your SCADA or PLC.
Product Spotlight for Treatment Tank Level Measurement
Why Treatment Tank Level Measurement Matters
Tank level is one of the most widely used control signals on a treatment works. Continuous level measurement allows operators to:
Control inflow and outflow — manage balancing and buffer tanks so downstream processes receive a steady, predictable feed
Protect pumps and process equipment — prevent dry-running at low level and overflow at high level in clarifiers, sumps and aeration basins
Manage chemical dosing and storage — track the contents of hypochlorite, acid and coagulant tanks to plan deliveries and avoid running out
Reduce manual inspection — replace dip-stick checks and site visits with continuous remote readings
Feed SCADA and telemetry — pass level data to the control system over 4–20 mA, with HART® for remote configuration on selected models
Level Transmitters for Every Treatment Tank Application
Screw-in Transmitters for Tank Walls and Pipework
Screw-in transmitters mount into the tank wall or a pipe connection near the base, so there is no cable to hang in the liquid. They suit dosing, storage and buffer tanks where the pressure at the base of the liquid column is measured as level:
LMK 351 Screw-in Level Transmitter
Pressure range 0–40 mbar to 0–20 bar with a capacitive ceramic sensor element. The PVDF pressure port is intended for aggressive media, and a G 1½″ process connection is available for pasty and polluted media. Outputs are 2-wire 4–20 mA or 3-wire 0–20 mA / 0–10 V. A sound choice for chemical dosing tanks and sludge-laden process tanks.
LMK 331 Screw-In Level Transmitter
Pressure range 0–400 mbar to 0–60 bar, with a G 3/4″ flush connection for pasty or contaminated media and a PVDF option for aggressive substances. Intrinsically safe (Ex ia) and SIL 2 compliant versions are available, with 2-wire 4–20 mA or 3-wire outputs.
LMP 331 Screw-In Level Transmitter
Pressure range 0–100 mbar to 0–40 bar with 0.1% FSO accuracy, a G 3/4″ flush pressure port and low thermal effect. Suited to process tanks where tighter accuracy supports inventory and dosing control. Ex ia and SIL 2 compliant versions available.
LMP 331 i Precision Screw-in Level Transmitter
Pressure range 0–400 mbar to 0–40 bar with a 1:10 turn-down ratio, 16-bit analogue-to-digital converter and a compensated temperature range of −20 to 80 °C. The communication interface allows offset, span and damping to be adjusted, which helps tune the signal for tanks with surface turbulence or foam.
Plastic Submersible Probes for Aggressive Chemicals
Where acids, lyes and other aggressive media are stored or dosed, plastic-bodied probes avoid the compatibility problems that stainless steel can face. Always check the wetted materials against your specific chemical and concentration before specifying:
LMK 809 Plastic Level Transmitter for Aggressive Media
Pressure range 0–0.4 mH2O to 0–100 mH2O in a 45 mm diameter body. Housing in PP-HT or PVDF with a 99.9% Al2O3 ceramic diaphragm, designed for viscous and aggressive media including acids and lyes. Output 2-wire 4–20 mA or 3-wire 0–10 V.
LMK 806 Plastic Level Transmitter for Aggressive Media
A compact 21 mm diameter probe with a flush ceramic sensor, ranging from 0–6 mH2O up to 0–100 mH2O and a 2-wire 4–20 mA output. Its slim body fits narrow dip tubes and small chemical tanks.
LMK 858 Separable Plastic Level Transmitter
Pressure range 0–40 cmH2O to 0–100 mH2O in a 45 mm PP-HT body with an optional 99.9% Al2O3 diaphragm. The detachable cable assembly simplifies installation and replacement, and integrated lightning protection (8 kA gas discharge tube, 4 kV surge protection to EN 61000-4-5) helps on exposed outdoor tanks.
LMP 808 Separable Plastic Level Transmitter
Pressure range 0–1 mH2O to 0–100 mH2O in a 35 mm plastic probe with a stainless steel piezoresistive sensor and detachable cable. SIL 2 compliant with integrated lightning protection, and available with 2-wire 4–20 mA or 3-wire outputs.
Stainless Steel Probes and HART® Communication for Process Tanks
For clarifiers, aeration basins, balancing tanks and wet wells holding process water or effluent, submersible stainless steel probes are a dependable general-purpose choice, with HART® or digital adjustment where remote configuration is useful:
LMK 358 H Separable Stainless Steel Level Transmitter with HART® Communication
Pressure range 0–60 cmH2O to 0–100 mH2O in a 39.5 mm body, with a capacitive ceramic sensor and 99.9% Al2O3 diaphragm. HART® communication allows settings to be configured remotely, it operates up to 85 °C, and an Ex ia intrinsically safe version is available. The separable design uses a mounting flange with cable gland.
LMK 307 Stainless Steel Level Transmitter
Pressure range 0–4 mH2O to 0–250 mH2O in a 27 mm stainless steel probe with a flush ceramic sensor. Good linearity and long-term stability, 2-wire 4–20 mA or 3-wire outputs, and Ex ia and SIL 2 compliant versions. A straightforward choice for deep basins and wet wells.
LMP 308 i Separable Stainless Steel Level Transmitter Precision
Pressure range 0–4 mH2O to 0–200 mH2O in a 35 mm body with a detachable cable and sensor head. Accuracy of 0.2% FSO TC, a 1:10 turn-down ratio and a compensated range of −20 to 70 °C, plus a communication interface and an Ex ia version.
Heavy-Duty Hydrostatic Option for Deep or Large Tanks
For larger or deeper tanks where a robust, fully submersible sensor is preferred:
CPA-325S Hydrostatic Level Transmitter
Measurement range 0–1 mH2O up to 0–250 mH2O with ±0.35% of span accuracy. A thickened Ø48 mm 316L stainless steel diaphragm sits in a Ø76 mm probe body, rated IP68 with an operating temperature of −40 to +125 °C. Standard 2-wire 4–20 mA output, with PVC, PUR, FEP or TPE-U cable options.
Certifications & Compliance
Approvals vary by model, so confirm the specification of the transmitter you select. Across the products featured on this page, the following are available:
Intrinsically safe (Ex ia) — versions of the LMK 351, LMK 331, LMP 331, LMP 331 i, LMK 358 H, LMK 307 and LMP 308 i for gas and dust atmospheres
ATEX / IECEx — approvals stated for the LMP 331 i
SIL 2 — IEC 61508 / IEC 61511 compliance on the LMK 331, LMP 331, LMK 307 and LMP 808
EN 61000-4-5 — surge protection on the LMK 858 and LMP 808
IP68 — fully submersible rating on the CPA-325S