Pressure Transmitters for Water Treatment Filtration Monitoring

Filters and membranes in water and wastewater treatment rarely fail suddenly. They foul gradually, and the first sign is usually a rising pressure drop. Reliable pressure measurement across sand and media filters, cartridge and bag filters and UF/RO membrane skids shows when a filter is loading up, so backwashes, chemical cleans and element changes happen when the data says they should rather than on a fixed timer.

Stork Solutions supplies differential, gauge and wireless pressure transmitters, plus digital gauges for local readout, covering everything from low-range differential measurement across fine filters to high static pressure on membrane feed lines. Output options include 4 … 20 mA, 0 … 10 V, Modbus RTU and HART®, so signals can go straight to your PLC or SCADA system.

Product Spotlight for Water Treatment Filtration Monitoring

Why Filtration Pressure Monitoring Matters in Water Treatment

Every filtration stage in a treatment works depends on pressure readings to show what is happening inside the vessel or housing. Continuous measurement allows operators to:

  • Detect fouling and blinding — a steadily rising differential pressure across a sand, media, cartridge or bag filter shows loading before filtrate flow or quality suffers

  • Control backwash on demand — start backwash from a differential pressure setpoint, with time as a backstop, to avoid wasting water and energy on unnecessary cycles

  • Protect membranes — track feed, inter-stage and concentrate pressures on UF and RO skids so cleaning is scheduled from trends rather than guesswork

  • Safeguard pumps and dosing lines — pump discharge and chemical dosing pressure reveal blocked lines, valve faults and loss of prime early

  • Support reporting and remote operation — feed trend data into SCADA, including from outlying pumping and filter sites

Pressure Transmitters for Every Water Treatment Filtration Application

Differential Pressure Across Filters and Membrane Skids

Differential pressure is the primary fouling indicator. Connect a transmitter across the inlet and outlet of a filter vessel, cartridge housing or membrane stage to track loading as it builds:

DPT 100 Differential Pressure Transmitter
Differential pressure from 10 mbar to 20 bar, withstanding static pressures of up to 400 bar. 2-wire 4 … 20 mA output with an optional RS485 Modbus RTU interface. Compact aluminium die-cast case with zero adjustment by button. A practical choice for media filter banks and cartridge or bag filter housings where a simple loop or Modbus signal is needed.

DPT 200 Differential Pressure Transmitter with HART® Communication
Differential pressure from 1 mbar to 20 bar with a maximum static pressure of 400 bar and rangeability up to 100:1. 4 … 20 mA output with linear or square root extraction, plus an optional LC display and stainless steel housing. The low end of the range suits fine filters with small pressure drops, while HART® allows ranges to be set remotely.

DMD 331 Differential Pressure Transmitter
Differential pressure from 0 … 20 mbar to 0 … 16 bar with 4 … 20 mA or 0 … 10 V output. Piezoresistive stainless steel sensor with 316L wetted parts, suitable for wet/wet differential applications and listed for water treatment. Withstands up to 30 times its differential pressure range, which helps when backwash surges and valve changes hit the sensor.

Feed, Pump Discharge and Chemical Dosing Lines

Gauge pressure on feed pumps, filter headers and dosing lines shows the condition of the system the filters depend on, and gives context to every differential reading:

DMK 331 Industrial Pressure Transmitter
Pressure range 0 … 400 mbar to 0 … 600 bar with a ceramic sensor. The G 1/2″ flush port is intended for pasty or polluted media, such as sludge-laden or raw water lines, and an open-port PVDF version is available for aggressive media, which is worth considering on dosing lines. Output options include 4 … 20 mA, 0 … 20 mA and 0 … 10 V.

DMK 351 P Pressure Transmitter
Pressure range 0 … 40 mbar to 0 … 20 bar with a capacitive ceramic sensor and 99.9% Al₂O₃ diaphragm. Flush-mounted design with G1 1/2″, dairy pipe and Clamp connection options, and high overpressure capability. A good match for low-pressure backwash, filtrate and thickened sludge lines where a flush diaphragm avoids dead pockets.

Local Indication and Switching at the Filter

Operators working at a filter bank or membrane skid benefit from a reading where they are standing, and from contacts that can raise an alarm or start a backwash sequence:

DMD 831 Differential Pressure Transmitter with Display and Contact
Differential range up to 0 … 70 bar, with a 4-digit red LED display selectable between positive pressure, negative pressure and differential pressure. 3-wire 4 … 20 mA output, switching accuracy ≤ ±0.5% FSO, 316L stainless steel pressure port and IP 65 protection. Media temperatures from -40 … 125 °C. Suits a filter alarm or backwash trigger with local display.

BAROLI 02 P Battery Powered Digital Pressure Gauge
Pressure range 0 … 100 mbar to 0 … 40 bar with a 2-line LC display, min/max function with reset, configurable pressure units and a rotatable housing. Stainless steel flush diaphragm. Battery powered, so it is useful for spot checks, commissioning and verifying a filter reading without adding wiring.

Wireless Monitoring for Remote and Retrofit Sites

Where cable runs are impractical, such as outlying pumping stations, standalone filter units or retrofits to existing skids, a wireless transmitter avoids trenching and conduit:

IWPT Wireless Pressure Transmitter
Gauge pressure from -1 to +400 bar for liquids and gases, with a wireless range of up to 500 m line-of-sight (depending on receiver) and five years of battery life at a 10-second update rate. 316 stainless steel housing with Viton seals and IP68 protection. Receivers provide analogue, digital, RS-232/485, Ethernet and USB outputs, so readings can reach your control system.

Certifications & Compliance

Approvals differ by model, so confirm the requirement for your duty when specifying. The products above offer:

  • ATEX / IECEx — intrinsically safe (Ex ia) versions of the DMK 331 and DMK 351 P; Ex ia options on the DMD 331 and Ex ia / Ex d options on the DPT 200, for hazardous areas on treatment sites

  • SIL 2 — the DMK 331 is compliant to IEC 61508 / IEC 61511 for safety-related functions

  • IP65 and IP68 ingress protection — IP 65 on the DMD 831 and IP68 on the IWPT

  • Potable water material approvals — not listed on the product pages above. If your scheme requires a specific drinking water approval, contact us with the approval and model and we will confirm what is available

Sign Up For Our Newsletter!
Send through your product enquiry

Thank you for visiting Stork Solutions.

Please fill in the form and send through your enquiry. If you are interested in multiple products then please add the details into the message section.

We look forward to receiving your enquiry.

Thank you

Stork Solutions