Level Sensors for Early Flood Warning Systems

For water and drainage operators, an early flood warning system is only as good as the level data feeding it. Culverts, open channels, outfalls, storm tanks and sewer chambers can go from normal to critical in minutes, and the people responsible need an alarm while there is still time to act, not a record of what happened afterwards.

Stork Solutions supplies level sensors for early flood warning systems across drainage and stormwater networks, from rotary encoder level sensors with SDI-12 output for channels and culverts, to submersible probes with analogue, SDI-12 or Modbus outputs for wet wells, storage and outfalls. Pair them with remote monitoring units and you have level alarms reaching operators wherever the site is.

Product Spotlight for Early Flood Warning Systems

Why Early Flood Warning Systems Matter

A flood warning is only useful if it arrives early and can be trusted. Continuous level measurement across the drainage network lets operators:

  • Catch rapid rises — set rate-of-rise alarms on culverts and channels so a fast-developing event is flagged before a fixed high-level threshold is reached

  • Warn before surcharge — track levels in sewer chambers and stormwater storage so a rising network is spotted ahead of surcharge and overflow

  • Protect remote assets — monitor outfalls and unmanned sites without a call-out, using low-power sensors that suit solar or battery-fed telemetry

  • Trigger the right response — use multi-stage alarm thresholds and relay outputs to alert control rooms and on-call staff

  • Integrate with existing systems — bring level data into SCADA and data loggers over SDI-12, Modbus RTU or 4–20 mA

Level Sensors for Every Flood Monitoring Application

Channels, Culverts and Open Watercourses

Where a submersible probe would sit in debris, silt or fast flow, a rotary encoder level sensor above the water is often the more practical choice. Both encoders below report position digitally over SDI-12, which keeps wiring simple on remote telemetry sites.

E24R-155 SDI-12 Digital Rotary Encoder Level Sensor
SDI-12 (version 1.4) output with 0.01% of full scale accuracy, equivalent to 1 mm over a 10 m range. Rotation speed up to 10,000 rpm, 8 mm steel shaft and anodised aluminium body, with a 2 m screened PVC cable as standard (other lengths available). An internal battery backup preserves position memory through power outages, which suits unattended culvert and channel sites.

E24R-150 SDI-12 Digital Rotary Encoder
A low-power SDI-12 rotary encoder with internal battery backup, 8 mm steel shaft and lightweight anodised aluminium body. Rotation speed up to 10,000 rpm and a wide operating temperature range. A straightforward option for connecting channel and river-style level measurement to data loggers.

Outfalls, Wet Wells and Stormwater Storage

For fixed installations below the water surface, submersible probes give a direct hydrostatic level reading. The range below covers low-power SDI-12 sites through to analogue loops feeding existing outstations.

SLS-SD Submersible Level Sensor – Digital Output
Level ranges from 0.5 mWG to 100 mWG with SDI-12 version 1.4 output and level and temperature output as standard. Draws less than 250 µA idle and less than 4 mA active, so it suits solar and battery-powered sites. 316 stainless steel housing, PUR submersible cable and IP68 rating for full submersion to 100 m depth.

SLS-SA Submersible Level Sensor – Analogue Output
Ranges from 0.5 mWG to 100 mWG with 4–20 mA (2-wire), 0–5 V / 0–10 V (3-wire), 0.5–4.5 V ratiometric or low-power millivolt outputs. Accuracy options down to better than ±0.1%, 316 stainless steel housing and IP68 rating. Optional temperature output. A natural fit for RTUs and PLCs that already take analogue level signals.

LMK 382 Stainless Steel Level Transmitter
Specified for sewage, viscous and pasty media, with ranges from 0–40 cmH₂O to 0–200 mH₂O and 4–20 mA or 0–10 V outputs. 39.5 mm diameter with a 99.9% Al₂O₃ diaphragm, an optional Pt 100 temperature element and a flange version available. Suited to combined sewer chambers, pumping stations and storm tanks where solids are present.

LMP 307 Stainless Steel Level Transmitter
Nominal ranges from 0–1 mH₂O up to 0–250 mH₂O, with 4–20 mA, 0–20 mA or 0–10 V outputs. 26.5 mm diameter stainless steel body with small thermal effect and good long-term stability. A compact choice for narrow stilling wells and boreholes in drainage and stormwater applications.

Digital Probes and Pressure Points on the Network

Digital outputs avoid analogue signal loss over long cable runs and make it easier to put several measurement points on the same network. Two options cover Modbus and SDI-12 installations.

DCL 531 Stainless Steel Probe with RS485 Modbus RTU
Level range 1 to 250 mH₂O with accuracy of ≤ ±0.25% FSO and a 500 Hz measurement rate, useful for picking up fast level changes. 9–32 VDC supply, 26.5 mm diameter stainless steel body and IP68 ingress protection. A drinking water certificate (DVGW and KTW) is available. Suits Modbus RTU based SCADA and PLC systems at pumping stations and storage tanks.

TPT-SDI Pressure Transmitter with SDI-12
Native SDI-12 version 1.4 output, 0.5 to 600 bar ranges (gauge, sealed gauge or absolute) and accuracy of ≤±0.25% FS (≤±0.10% FS optional). 6–36 V DC supply with less than 250 µA idle and less than 4 mA active. Integrated lightning protection and IP67 rating. Use it where a pressure reading is needed on the same SDI-12 logger as your level sensors.

Telemetry and Flood Alarms

A level sensor only protects the network when its reading reaches someone. These remote monitoring units take level signals from the sensors above and send alarms and data back to operators.

ECHO4 Remote Monitoring System
Four analogue inputs (4–20 mA and 0–10 V) with GSM/GPRS telemetry to the ECHOVIEW cloud platform using a multi-network SIM for rural coverage. Two relay outputs for alarming or control, email alerts when thresholds are breached, and IP67 self-contained enclosure. Solar panel compatible options available. Pairs naturally with analogue outputs such as the SLS-SA or LMK 382.

ECHO-IoT Remote Monitoring Gateway
Four analogue inputs, eight digital inputs and Modbus-enabled instruments over RS-232, RS-485 or Ethernet, with four relay contacts. MQTT and Modbus RTU/TCP/IP communications over a 2G/3G/4G cellular modem, email or SMS alarm messages, and IP67 rating. 12–36 Vdc supply. Suited to larger sites that combine several sensors and need local display and SCADA-style reporting.

Certifications & Compliance

Approvals vary by model, so confirm the certification you need on the individual product page. Across the range featured here, the following are available:

  • SDI-12 version 1.4 — digital output on the SLS-SD, TPT-SDI and E24R-155 for low-power telemetry sites

  • IP68 — full submersion rating on the SLS range and DCL 531 probe (SLS rated to 100 m depth)

  • DVGW and KTW — drinking water certificate available on the LMP 307 and DCL 531 for potable water storage and network applications

  • Ex ia — intrinsically safe option available on the LMK 382 for hazardous areas such as wet wells and pumping stations with gas risk

  • SIL 2 — functional safety version listed for the LMP 307

  • IP67 — enclosure or body rating on the ECHO4, ECHO-IoT and TPT-SDI

Sign Up For Our Newsletter!
Send through your product enquiry

Thank you for visiting Stork Solutions.

Please fill in the form and send through your enquiry. If you are interested in multiple products then please add the details into the message section.

We look forward to receiving your enquiry.

Thank you

Stork Solutions