Pressure Transmitters for Distribution Network Pressure Regulation
Potable water only reaches customers reliably when pressure across the distribution network is held within a controlled window. Too high, and pipes, joints and fittings are stressed and leakage rises; too low, and supply suffers at the highest or most distant properties. Accurate pressure measurement at pressure reducing valve (PRV) stations, booster pumping stations, district metered area (DMA) inlets and reservoirs gives operators the feedback they need to regulate that window.
Stork Solutions supplies pressure transmitters for wired, digital and wireless installations across the network, from mains chambers with no mains power to pumping stations with full SCADA integration. This page groups the options by how they are installed and connected, so you can match the transmitter to the site rather than the other way round.
Product Spotlight for Distribution Network Pressure Regulation
Why Distribution Network Pressure Regulation Matters
Pressure is the main control variable in a water distribution network, and reliable measurement at key points lets water companies and contractors to:
Reduce leakage — hold downstream pressure at the level the network actually needs, rather than the level the source happens to deliver
Prevent bursts — spot sustained over-pressure and rapid swings before they fatigue pipework and joints
Detect surges and transients — capture pressure peaks caused by pump starts, valve operation and sudden demand changes
Verify PRV and pump performance — compare inlet and outlet pressure to confirm valves and boosters are doing what the control settings say
Extend telemetry to remote sites — feed pressure data from chambers and DMA boundaries into SCADA or RTU systems without new cabling
Pressure Transmitters for Every Distribution Network Application
PRV Stations, Boosters and Mains Chambers (Wired 4–20 mA)
Where power and a signal cable are already available, loop-powered transmitters remain the simplest way to bring inlet and outlet pressure into a local controller or SCADA system:
DMP 331i / DMP 333i Precision Pressure Transmitter
Pressure range 0–400 mbar to 0–600 bar, with a 2-wire 4–20 mA output or a 3-wire 0–10 V output. Digital electronics with a 16-bit analogue-to-digital converter allow offset, span and damping to be adjusted digitally, with a 1:10 turn-down ratio. A sound general-purpose choice for PRV inlet and outlet points and booster station discharge lines. Intrinsically safe Ex ia versions are available.
DMP 335 Industrial Pressure Transmitter
Pressure range 0–10 bar to 0–600 bar. A welded stainless steel sensor removes the need for a fluid fill, and the design is insensitive to pressure peaks with high overpressure capability. That makes it a good fit for pump delivery lines and other points exposed to transients. 2-wire 4–20 mA or 3-wire 0–10 V outputs, with Ex ia versions available.
Remote and Battery-Powered Telemetry Sites (SDI-12)
District metered area boundaries and isolated valve chambers are often run from a battery or solar-powered RTU or logger. A low-power digital transmitter avoids analogue conversion and keeps the energy budget small:
Titan TPT-SDI Pressure Transmitter with SDI-12
Native SDI-12 (version 1.4) output on a 6–36 V dc supply, drawing under 250 µA idle and under 4 mA active. Ranges from 0.5 to 600 bar in gauge, sealed gauge or absolute. Standard accuracy is ≤±0.25% FS, with ≤±0.10% FS optional. A ceramic piezo-resistive sensing element sits behind a stainless steel body, with G¼” DIN 3852, ¼” NPT or Series 21 quick release process connections and ingress protection up to IP67. Described by the manufacturer as suited to RTUs and remote battery or solar installations.
Wireless Monitoring Where Cabling Is Impractical
Trenching a cable to a chamber, break pressure tank or hillside reservoir can cost more than the instrument. Battery-powered wireless transmitters send pressure readings back to a receiver up to 500 metres away (line-of-sight):
IWPT Wireless Pressure Transmitter
Range -1 to +400 bar gauge in a 316 stainless steel housing with a ceramic piezo-resistive sensor, Viton seals and IP68 ingress protection, for liquids and gases. Battery life is five years at a 10-second update rate. It pairs with IWR receivers using DIL switch pairing, and receiver outputs include analogue, digital, RS-232/485, Ethernet and USB. Each unit is temperature compensated, calibrated and supplied with a traceable serial number.
IWmAT Wireless 4-20mA Transmitter
Turns an existing wired 4–20 mA sensor into a wireless point, with line-of-sight range up to 500 metres and a five-year battery life at a 10-second update rate. Works with the IWR-1, IWR-5 and IWR-PORT receivers, and alarm functions are supported through the receiver clean contacts. Useful for adding wireless telemetry to transmitters already installed.
Modbus Integration and Reservoir Monitoring
For pumping stations with a Modbus network, and for storage reservoirs where level is monitored alongside network pressure, these two options extend the picture:
DCT 531 i Precision Pressure Transmitter with RS485 Modbus RTU
Ranges from 0–100 mbar to 0–400 bar (gauge or absolute) with an RS485 Modbus RTU output carrying both pressure and temperature values. Accuracy is ±0.10% FSO for ranges of 0.25 bar and above, on a 9–32 VDC supply with IP67 ingress protection and stainless steel and EPDM seals. Suited to digital integration at pumping stations and control kiosks.
LMP 307 i Stainless Steel Level Transmitter
A 26.5 mm diameter submersible transmitter with a stainless steel sensor, ranging from 0–4 mH2O to 0–200 mH2O, with 4–20 mA or 0–10 V outputs. It is drinking water certified (DVGW, KTW), which makes it a suitable choice for reservoirs and service tanks holding potable water.
Certifications & Compliance
Approvals depend on the transmitter selected. Those shown on the product pages for the models above are:
DVGW and KTW — drinking water certification for the LMP 307 i level transmitter
ATEX / IECEx — intrinsically safe (Ex ia) versions of the DMP 331i / DMP 333i and DMP 335, for chambers and pumping stations where a hazardous atmosphere may be present
IP67 to IP68 ingress protection — IP67 on the TPT-SDI (up to) and DCT 531 i, and IP68 on the IWPT, for damp or occasionally flooded chambers
If a transmitter will be in direct contact with drinking water, tell us the approval you need (for example, a national drinking-water material scheme) and we will confirm the suitable model.