Pressure Transmitters for Hydrogen Refuelling Pressure Monitoring

Hydrogen refuelling stations move gas through compression, buffer and cascade storage and dispenser lines at very high pressures. Reliable pressure monitoring at each stage keeps the station controlled, protects the equipment and gives early warning of faults, and the transmitter has to cope with hydrogen itself as well as the pressure.

Stork Solutions supplies pressure transmitters built for hydrogen service, with stainless steel and gold-plated wetted parts, digital Modbus output for station control, and ATEX/IECEx and SIL 2 options where the product is approved for them. We also supply the T8999 hydrogen leak detector for checking joints and components. Talk to us about your station layout and we will help you choose the right range, output and approvals.

Product Spotlight for Hydrogen Refuelling Pressure Monitoring

Why Hydrogen Refuelling Pressure Monitoring Matters

Pressure is the main control variable at a hydrogen station, and hydrogen is a demanding gas to measure. Continuous, accurate pressure measurement lets operators:

  • Control compression and storage — track pressure in compressor stages and cascade or buffer storage so filling sequences stay within limits

  • Monitor dispenser and nozzle lines — follow pressure during fills and spot abnormal behaviour on the delivery line

  • Resist hydrogen damage — use wetted parts chosen to prevent hydrogen embrittlement and permeation, which can otherwise cause drift or leakage

  • Work safely in hazardous areas — specify ATEX/IECEx and intrinsically safe versions for zones where hydrogen may be present

  • Integrate with station control — feed digital pressure data into the station PLC or SCADA, and find leaks early with dedicated detection equipment

Pressure Transmitters for Every Hydrogen Refuelling Application

Hydrogen-Specific Transmitters for Compression, Storage and Dispensing (up to 1000 bar)

For measuring points that carry hydrogen directly, these transmitters are designed with hydrogen in mind:

DMP 336 Industrial Pressure Transmitter
Nominal gauge ranges from 16 to 1000 bar, with overpressure up to 1500 bar and burst pressure up to 3000 bar. The 316L stainless steel housing and wetted parts are designed to prevent hydrogen embrittlement and leakage. Oil and grease free to ISO 15001, with a 2-wire 4 … 20 mA output. ATEX/IECEx certified with an optional zone 0 Ex ia version, and compliant with SIL 2 to IEC 61508 / IEC 61511.

DMP 333P Pressure Transmitter
Gauge ranges of 60 and 100 bar and absolute ranges from 60 to 600 bar, with overpressure protection up to 1000 bar. A gold-plated process connection and diaphragm are available for hydrogen applications. Accuracy is 0.35 % FSO as standard, with 0.25 % FSO optional, and the operating temperature range is -40 to 125 °C. Suitable for lower-pressure supply lines and storage points. ATEX/IECEx capable.

Digital Modbus Output and Very High-Pressure Lines

Station control systems often prefer a digital signal, and the highest-pressure lines call for a dedicated high-pressure design:

DCT 541 Industrial Pressure Transmitter
Ranges from 0 … 16 bar up to 0 … 1000 bar with 0.5 % FSO accuracy. The RS485 output with Modbus RTU protocol uses a master-slave architecture supporting up to 247 slaves, so one bus can serve several measuring points. Wetted parts of special stainless steel are designed to prevent hydrogen embrittlement and permeation. Oil and grease free to ISO 15001 and insensitive to pressure peaks, which suits fast fill cycles.

DMP 334 Industrial Pressure Transmitter and DMP 334 i Precision Pressure Transmitter
Both cover ranges from 0 … 600 bar to 0 … 2200 bar with a welded thin-film sensor and M20 x 1.5 or 9/16 UNF pressure ports. The DMP 334 is ATEX/IECEx approved with an intrinsically safe Ex ia version for gases and dusts. The DMP 334 i adds a 1:10 turn-down ratio and a communication interface for adjusting offset, span and damping. Hydrogen suitability is not stated on these product pages, so please confirm your medium with us before specifying.

Hydrogen Leak Detection

Pressure monitoring shows that something has changed; leak testing finds where. For joints, fittings and components on station pipework and assemblies:

T8999 Hydrogen Leak Detector
Offers 1 cc/h sensitivity, independent of the pressure and the volume being tested. It uses a 5 % hydrogen mix, which is not explosive or dangerous for the work environment. Combines absolute decay leak testing with leak identification, using an aluminium probe with warning LED and buzzer. Connectivity includes USB, RS232, RS485, Profinet, EtherNet IP and EtherCAT.

Certifications & Compliance

Approvals depend on the transmitter, so we match the model to your station’s hazardous-area classification. The products featured here are supported by the following:

  • ATEX / IECEx — DMP 336, DMP 333P (capable), DCT 541, DMP 334 and DMP 334 i

  • Ex ia intrinsically safe — optional zone 0 version of the DMP 336, and an Ex ia version of the DMP 334 for gases and dusts

  • SIL 2 — DMP 336, compliant with IEC 61508 / IEC 61511

  • ISO 15001 — oil and grease free construction on the DMP 336 and DCT 541