Pressure Transmitters for Fuel Cell System Pressure Regulation

A fuel cell stack only performs well when the gases entering it are held at controlled pressures. Hydrogen is stepped down from storage or supply pressure through one or more regulator stages, while air or another oxidant is delivered to the cathode side, and the control unit needs reliable pressure feedback at each point to keep the stack within its operating window.

Stork Solutions supplies pressure transmitters and compact OEM pressure sensors for fuel cell test benches, stationary power units and mobile systems. This page shows how to match pressure range, wetted materials and output signal to each stage of the gas supply, from high-pressure hydrogen inlets through to low-pressure stack feeds and digital links to the control unit.

Product Spotlight for Fuel Cell System Pressure Regulation

Why Fuel Cell System Pressure Regulation Matters

Pressure is the main variable the control system works with when it manages a fuel cell. Accurate, stable measurement at the right points in the circuit allows engineers to:

  • Control regulator stages — monitor pressure upstream and downstream of each pressure-reducing stage so the delivered hydrogen pressure stays on target

  • Balance anode and cathode pressure — give the controller matched feedback from the hydrogen and air or oxidant sides of the stack

  • Protect the stack and balance of plant — detect over-pressure, pressure loss and abnormal trends before they affect components

  • Keep the gas path clean — specify oil and grease-free wetted parts where contamination must be avoided

  • Integrate with the control unit — use analogue or digital outputs to feed PLCs, embedded controllers and test bench data logging

Pressure Transmitters for Every Fuel Cell Application

Hydrogen Supply and Pressure-Reducing Stages (16 to 1,000 bar)

Measuring hydrogen at storage or inlet pressure calls for materials designed for the gas. For background on why, see our article on measuring hydrogen pressure and the effects of hydrogen migration. These transmitters are intended for hydrogen service:

DCT 541 Pressure Transmitter for Technical Gases and H2 Applications
Nominal pressure from 0–16 bar up to 0–1000 bar with 0.5 % FSO accuracy. Wetted parts of special stainless steel, oil and grease free to ISO 15001, with materials selected to prevent hydrogen embrittlement and permeation. RS485 output with Modbus RTU makes it a good fit for a regulator inlet that reports directly to the control unit.

DMP 336 Pressure Transmitter for Technical Gases and H2 Applications
Nominal gauge ranges from 16 to 1000 bar, with stainless steel 316L housing and wetted parts, oil and grease free to ISO 15001 and a design that prevents hydrogen embrittlement. Standard 2-wire 4 … 20 mA output with short-circuit and reverse polarity protection. An optional IS version is available for Zone 0/20 areas.

DMP 333P Pressure Transmitter for Hydrogen Applications
Nominal pressure from 0–60 bar up to 0–600 bar, with 4 … 20 mA (2-wire) or 0 … 10 V (3-wire) output. An optional gold-plated process connection and diaphragm is available for hydrogen service. Response time is 10 ms or less (2-wire) and 3 ms or less (3-wire), which suits pressure-reducing stages that need quick feedback.

Low-Pressure Stack Feeds and Air Supply (0.1 to 6 bar and above)

Downstream of the regulator, anode and cathode pressures are usually low and need fine resolution. Check the wetted materials against your gas and operating conditions before specifying these models, as hydrogen suitability is stated only for the transmitters in the previous section.

18.601 G OEM Pressure Transmitter Low Pressure
Nominal gauge pressure 0.1 to 6 bar (0 … 100 mbar to 0 … 6 bar) with overpressure up to 21 bar. Piezoresistive stainless steel sensor, FKM seals and a stainless steel diaphragm, with a 4 … 20 mA output and 10 ms or less response time. Suited to compact OEM builds and low-pressure supply lines.

DCT 531 i Precision Pressure Transmitter
Nominal ranges from 0…100 mbar to 0…400 bar in gauge or absolute, with accuracy of ±0.10 % FSO for ranges of 0.25 bar and above. Described as suited to non-aggressive gases and liquids, with IP67 protection and a compact design. A good choice for air and oxidant supply measurement.

Digital Outputs for the Control Unit

Digital interfaces reduce wiring and let the controller read pressure alongside other system data. Stork Solutions offers both Modbus RTU and I²C options:

DCT 541
RS485 with Modbus RTU, in a master-slave arrangement supporting up to 247 slave devices, so several hydrogen pressure points can share one bus.

DCT 531 i
RS485 with Modbus RTU delivering pressure and temperature, with a 9 – 32 VDC supply.

DCT 532 Industrial Pressure Transmitter with I²C Interface
Ranges from 0 to 100 mbar up to 0 to 400 bar in 316L stainless steel. The I²C master-slave topology supports up to 127 devices at a maximum frequency of 400 kHz, with customisable slave address and data format.

Compact OEM Integration

For fuel cell modules where space is limited, these sensors integrate directly with the system electronics. Confirm media compatibility for your gas before specifying.

ME 782 Pressure Sensor with Signal Conditioning
Piezoresistive ceramic sensor with a 15-bit digital I²C output, powered from 3.3 or 5.0 VDC. Pressure ranges from 0.5 to 600 bar, response time of 5 ms or less, and absolute, gauge or sealed gauge versions. The diaphragm is Al₂O₃ ceramic or sapphire.

Titan TPTd Digital Pressure Transmitter
Ranges from 0.5 up to 600 bar with I²C and SPI support. Ceramic piezo-resistive sensing element in a stainless steel housing, IP67 protection, and high frequency response from 1 kHz up to 75 kHz. Supplied from 10–32 V dc, or as a 0.5 to 4.5 V ratiometric output from a 2.7–5.5 V dc supply.

Certifications & Compliance

Approvals depend on the model and variant, so check the product page for your chosen transmitter. Across the products featured above, the following are stated:

  • ATEX / IECEx — listed for the DCT 541 and DMP 333P; the DMP 333P intrinsically safe version is noted as in preparation

  • Intrinsically safe (Zone 0/20) and SIL 2 — optional IS version of the DMP 336, with SIL 2 to IEC 61508 / IEC 61511

  • ISO 15001 — oil and grease free wetted parts on the DCT 541 and DMP 336

  • IP67 ingress protection on the DCT 531 i and Titan TPTd

  • EMC / ESD — standards compliance stated for the ME 782

  • IEC 60770 — accuracy stated to this standard for the 18.601 G