Multi-Parameter Sensors and Transmitters for Indoor Air Quality Monitoring
The air inside a building is only as good as the data used to manage it. Carbon dioxide that builds up in a busy meeting room, humidity that drifts outside its band in a laboratory, or a room that quietly loses its pressure relationship with the corridor next door will all go unnoticed until occupants complain or an audit asks for records. Indoor air quality monitoring gives building services engineers and facilities teams continuous readings they can trend, alarm on and pass to the building management system, so ventilation can be adjusted on evidence rather than guesswork.
Stork Solutions supplies the instruments behind that picture for offices, laboratories, cleanrooms and other controlled spaces: the FEEL multi-parameter sensor for temperature, humidity, CO₂, optional VOC and differential pressure in one housing, low-range differential pressure transmitters and switches for room and duct pressure, and multichannel data loggers and an IoT gateway for recording, alarming and reporting. It forms part of our wider cleanroom and building automation (HVAC/BMS) range.
Product Spotlight for Indoor Air Quality Monitoring
Why Indoor Air Quality Monitoring Matters
Occupied spaces change by the hour as people arrive, doors open and plant cycles on and off. Measuring the room continuously, rather than relying on spot checks, helps facilities and validation teams to:
Ventilate on demand — CO₂ readings show when a space is genuinely occupied, so fresh air can be increased when needed and reduced when rooms are empty
Hold temperature and humidity in band — comfort, product storage and sensitive processes all depend on stable conditions that are measured, not assumed
Protect room pressure relationships — low-range differential pressure shows whether air is flowing from clean to less clean areas, or being contained where it should be
Spot filter and fan problems early — rising pressure drop across filters or falling duct pressure points to plant issues before the room conditions suffer
Keep a defensible record — logged, time-stamped data and alarms reported to the BMS or a remote server give auditors and occupants evidence of how the building performed
Sensors and Transmitters for Every Indoor Air Quality Monitoring Application
Multi-Parameter Room and Duct Sensing
Where several air quality values are needed at one point, a single multi-parameter sensor saves wall space, wiring and BMS points compared with separate instruments. Versions are available for mounting in the room itself or in the supply or extract duct.
FEEL Multi-Parameter Sensor
A modular sensor that records up to five values, combining temperature (±0.3 K) and humidity (±2%) with an internal CO₂ sensor, an optional VOC sensor and differential pressure with default ranges of 1, 10, 100 or 1000 hPa, each adjustable to 25, 50, 75 or 100% of the ordered range. The temperature and humidity probe comes in room-mount or duct-mount versions. Outputs are analogue with an optional RS485 Modbus interface and optional open collector switch output, and options include a high-resolution display and auto-zero using an internal solenoid. Configuration is via a micro USB interface.
Room Pressure and Pressure Cascade Monitoring
Cleanrooms, laboratories and isolation suites rely on small, stable pressure differences between neighbouring rooms. Measuring them needs a transmitter that resolves a few pascals reliably and feeds a standard signal to the BMS or a local display.
Differential Pressure Transmitter DPS
Selectable nominal ranges from 0.1 to 1000 hPa for over, negative and differential pressure in non-aggressive gases, with 1% FS accuracy as standard (0.5% FS from 1 hPa and 0.2% FS from 2.5 hPa optional). Outputs include 0…20 mA, 4…20 mA, 0…10 V, ±5 V or two-wire, with an optional square root output and optional LC display. Its listed applications include critical environment control in cleanrooms, isolation suites, laboratories and containment facilities.
PrimAtü 10 Low Range Differential Air Pressure Transmitter
A low-range differential air pressure transmitter with freely selectable unidirectional or bidirectional ranges up to 1000 hPa, 1% FS accuracy as standard (0.5% or 0.2% optional), and 0…10 V, 0…20 mA or 4…20 mA output. An LCD display and RS485 Modbus interface are optional, and it can be DIN rail or wall mounted. Confirm the lowest range for your room pressure application with Stork.
Duct, Filter and Fan Pressure in the Air Handling Plant
Good indoor air starts at the air handling unit. Watching the pressure drop across filters and the pressure in ducts and across fans shows when filters are loading or airflow is falling, and gives the BMS a clear trigger for maintenance or an alarm.
DMD 341 Differential Pressure Transmitter for Gases and Compressed Air in Compact Version
Differential pressure ranges from 0…6 mbar up to 0…1000 mbar for non-aggressive gases, with a 2-wire 4…20 mA or 3-wire 0…20 mA / 0…10 V output. Heating and air conditioning applications listed for it include monitoring pressure across filters, fans and ducts.
DS 233 Differential Pressure Switch for Gases and Compressed Air in Compact Version
An electronic differential pressure switch covering 0…6 mbar up to 0…1000 mbar, with one PNP contact as standard (one or two optional) alongside a 4…20 mA or 0…10 V analogue output. The rotatable 4-digit LED display gives a local reading at the plant, and HVAC is among its listed applications.
Logging, Alarming and BMS Reporting
Measurements only become useful once they are recorded, compared against limits and shared. Multichannel loggers collect signals from several sensors, raise alarms and pass data on over Modbus, while a gateway can send readings from remote or dispersed sites to a central server.
CMC-141 Multicon Multi Channel Data Logger & Controller
A touchscreen logger and controller that accepts up to 72 inputs from a choice of input and output cards, with 8 PID control options as standard. RS485 Modbus is standard, and an optional communications module adds Ethernet with Modbus TCP/IP and an embedded web server for viewing live values in a browser. With the logging licence it records 1 to 60 channels at up to 10 Hz into 1.5 GB of internal memory, with USB data download and email notifications.
CMC-N16 Multicon Multichannel Controller Data Logger
A compact Multicon with up to 4 analogue and 4 digital inputs, a graphical touchscreen and the same RS485 Modbus as standard, with optional Ethernet, Modbus TCP/IP and web server. It suits a single room or plant area where a handful of air quality and pressure signals need logging and local alarms.
ECHO-IoT Remote Monitoring Gateway
A gateway with four 4…20 mA or 0…10 V analogue inputs, eight volt-free digital inputs and four relay outputs, plus Modbus connection over RS-232, RS-485 or Ethernet. Data is sent by MQTT over a built-in cellular modem to a web-based SCADA project, with alarms by email or SMS. Confirm suitability for your building network and BMS with Stork.
Certifications & Compliance
Approvals and protection ratings vary by model and version, so confirm the options you need on the relevant product page or with our team. The products above offer the following:
CE marking — the DPS is CE marked to the Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU and RoHS Directive 2011/65/EU
IP54 ingress protection — DPS differential pressure transmitter, protection class II
IP65 ingress protection — PrimAtü 10 low range differential air pressure transmitter
IP67 ingress protection — ECHO-IoT remote monitoring gateway
Other products — ratings and approvals for the FEEL, DMD 341, DS 233, CMC-141 and CMC-N16 are available from our team on request