Differential Pressure Transmitters for HVAC Duct Pressure Measurement

In a variable air volume system, the air handling unit fan is only as efficient as the duct static pressure signal it is controlled from. Hold the setpoint too high and the supply fan runs harder than it needs to, wasting energy and adding noise; let the signal drift and terminal units at the far end of the index run are starved of air. The same low-range measurements tell building services engineers and facilities teams when filters are loading, whether a fan is actually moving air and whether supply air is leaving the coils at the right temperature.

Stork Solutions supplies low-range differential pressure transmitters, differential pressure switches, multi-parameter duct sensors, temperature transmitters, PID controllers and data loggers for air handling units, ductwork and plant rooms. Analogue 4…20 mA and 0…10 V outputs and optional RS485 Modbus interfaces suit direct connection to BMS outstations and variable speed drive control loops. For pressure cascades, barometric compensation and BMS integration across critical buildings, see our cleanrooms and building automation (HVAC/BMS) overview.

Product Spotlight for HVAC Duct Pressure Measurement

Why HVAC Duct Pressure Measurement Matters

Duct pressure is a small number with a large effect on running costs, comfort and air quality. Reliable measurement across the air handling unit and its distribution ductwork helps BMS integrators and facilities teams to:

  • Match fan speed to demand — a duct static pressure signal into a PID loop lets the variable speed drive slow the supply fan as VAV dampers close, instead of running at a fixed speed

  • Change filters on condition — differential pressure across each filter bank shows loading as it builds, so filters are replaced when they need it rather than on a calendar

  • Prove fan operation — a differential pressure switch across the fan gives the BMS a dependable airflow-proving or alarm input

  • Hold supply air temperature — duct temperature measurement after the coils closes the loop on heating and cooling valves and feeds energy calculations

  • Simplify BMS integration — standard analogue outputs and Modbus interfaces reduce signal conversion and make commissioning and trending quicker

Instruments for Every HVAC Duct Pressure Measurement Application

Duct Static Pressure and Low-Range Air Pressure

Static pressure in supply and extract ductwork is measured in pascals rather than bar, so the transmitter span needs to sit close to the design pressure to keep resolution where the fan control loop needs it. Selectable low ranges make it easier to match one instrument type across different duct systems.

PrimAtü 10 Low Range Differential Air Pressure Transmitter
Low gauge or differential pressure measurement on non-aggressive gases, with ranges up to 1000 hPa chosen as unidirectional or bidirectional at ordering (the product page quotes a lowest range of 0.3 hPa or 0.5 hPa, so confirm the smallest span with Stork). Output is 0…10 V, 0…20 mA or 4…20 mA, with optional RS485 Modbus and an optional LCD display. Standard accuracy is 1% FS with 0.5% and 0.2% options, and the IP65 housing mounts on DIN rail or a wall, with push-button correction of zero offset and amplitude.

Differential Pressure Transmitter DPS
Inductive low-pressure measurement of positive, negative and differential pressure from 0.1 hPa (10 Pa) to 1000 hPa in 25 selectable ranges. Outputs include 0…20 mA, 4…20 mA, 0…10 V, ±5 V and two-wire, with an optional square root output for flow across orifice plates or venturis. Options include damping, one or two relay limit contacts, an LC display and automatic zero adjustment at set intervals, and the product page lists pressure drop across filters, coils and dampers among its HVAC uses.

Filter Differential Pressure and Fan Proving

Differential pressure rises steadily as a filter loads, and the same measurement taken across a fan confirms it is delivering air. A transmitter provides a continuous trend for condition-based maintenance, while a switch with a local display gives a direct alarm or interlock at the air handling unit.

DMD 341 Differential Pressure Transmitter for Gases and Compressed Air in Compact Version
Differential pressure ranges from 0…6 mbar to 0…1000 mbar on non-aggressive gases and compressed air, using a piezoresistive silicon sensor in a compact aluminium housing. Output is 2-wire 4…20 mA or 3-wire 0…20 mA / 0…10 V, and heating and air conditioning is one of its listed application areas. Customer-specific versions are available.

DS 233 Differential Pressure Switch for Gases and Compressed Air in Compact Version
Differential pressure from 0…6 mbar to 0…1000 mbar with a rotatable, configurable 4-digit LED display, one or two PNP switching contacts and a 4…20 mA or 0…10 V analogue output. Its stated heating and air conditioning uses include air filters, fans and blowers, making it a practical filter alarm or fan-proving device with a local readout.

Supply Air Temperature and Multi-Parameter Duct Sensing

Supply and return air temperatures close the loop on heating and cooling coils, and combining several measurements in one duct-mounted sensor means fewer duct penetrations and less wiring back to the outstation.

FEEL Multi-Parameter Sensor
Configurable with differential pressure, temperature and humidity, CO₂ and VOC sensors in one unit. Differential pressure defaults are 1, 10, 100 and 1000 hPa, adjustable to 25, 50, 75 or 100% of the ordered range; temperature is accurate to ±0.3 K and humidity to ±2%. A room-mount or duct-mount probe is available for temperature and humidity, with a switchable analogue output, optional RS485 Modbus, an optional open collector switch output and an optional TFT display.

TTT Titan Temperature Transmitter
Integrates PT100, PT1000, NTC or PTC resistance thermometers or thermocouples in a rugged stainless steel enclosure rated up to IP66, with customisable probe lengths and process connections. Analogue (TTTa, 0.5…4.5 V) and digital (TTTd, I²C or SPI) variants are offered, and HVAC, climate control and building automation are among its listed applications. Confirm the probe and output configuration for duct mounting and your BMS inputs with Stork.

Fan and VSD Control, Logging and Alarms

Where the BMS outstation does not run the loop itself, a standalone PID controller can take the duct static pressure signal and drive the variable speed drive directly. A multi-channel logger records pressures and temperatures for commissioning, energy reviews and fault-finding.

PUR-94 Advanced PID Controller
Universal input for 0/4…20 mA, 0…10 V, RTD and thermocouple signals, with an analogue output of 0…20 mA, 4…20 mA, 0…10 V or 2…10 V alongside relay or SSR outputs and a 24 V DC supply output for the transmitter. PID control with auto-tuning and fuzzy logic, dual control loops and RS-485 Modbus RTU as standard, plus a large 20 mm LED display. Confirm the configuration for your fan and VSD with Stork.

CMC-141 MultiCon Multi-Channel Data Logger & Controller
A multi-channel logger and controller with a graphical touchscreen, up to 72 inputs from 27 input and output card types, and 8 PID control options in every device as standard. Data logging (licence key required) runs at rates from 0.1 s with 1.5 GB of internal memory, RS485 Modbus is standard, and the optional communications module adds Modbus TCP/IP over Ethernet, with a built-in web server for live readings in a browser.

Certifications & Compliance

Approvals and protection ratings vary by model and version, so confirm the options you need on the relevant product page or with our team. The products above offer the following:

  • CE marking — the DPS is CE marked to the Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU and RoHS Directive 2011/65/EU

  • IP65 ingress protection — PrimAtü 10 housing for plant room and AHU mounting

  • IP54 and protection class II — DPS ABS housing

  • Up to IP66 — TTT Titan stainless steel enclosure with cable outlet or M12 connector

  • IP 65/20 protection — PUR-94 Advanced PID Controller

Sign Up For Our Newsletter!
Send through your product enquiry

Thank you for visiting Stork Solutions.

Please fill in the form and send through your enquiry. If you are interested in multiple products then please add the details into the message section.

We look forward to receiving your enquiry.