Pressure and Temperature Transmitters for Energy Management and Optimisation

In commercial buildings, cleanrooms, laboratories and data centres, the fans, pumps, chillers and boilers that serve the HVAC system are among the largest users of energy on site. Much of that energy is lost quietly: pumps working against throttled valves or blocked strainers, chilled water delivered colder than the load needs, heating circuits held at a fixed temperature whatever the weather, and fans pushing air through loaded filters. Reliable pressure and temperature data from the water and air sides of the plant shows where the waste is, and gives the BMS the signals it needs to trim pump speeds, reset setpoints and plan maintenance.

Stork Solutions supplies pressure transmitters for chilled and heating water circuits, differential pressure instruments for pumps, heat exchangers and filters, and temperature transmitters for flow and return measurement, together with the controllers, data loggers and remote monitoring systems that turn those readings into trends, alarms and control actions. Outputs include 4…20 mA, 0…10 V and RS485 Modbus RTU for straightforward integration with building management systems. For the wider range, see our cleanroom and building automation page.

Product Spotlight for Energy Management and Optimisation

Why Energy Management and Optimisation Matters

Energy optimisation starts with measurement. Continuous pressure and temperature data from central plant and distribution systems allows building services teams to:

  • Run pumps to demand — differential pressure across a pump or at the index circuit lets variable speed drives slow down at part load instead of throttling flow against a fixed head

  • Reset water temperatures — flow and return temperatures show when the load allows warmer chilled water or cooler heating water, easing the work done by chillers and boilers

  • Change filters at the right time — filter differential pressure shows when rising resistance is adding to fan energy, rather than relying on a fixed replacement calendar

  • Catch plant faults early — trends in system pressure, pump head and temperature difference reveal leaks, fouled heat exchangers, blocked strainers and low delta T before they turn into comfort complaints

  • Prove the results — logged data gives a before and after record of changes to setpoints, schedules and control strategies

Instrumentation for Every Energy Management Application

Chilled and Heating Water System Pressure

Static pressure is the first thing to watch on a sealed chilled or heating water circuit: a slow fall points to a leak or a failing pressurisation unit, while pressure at pump suction and discharge shows how hard the pumps are working. Gauge pressure transmitters with a stainless steel wetted path give the BMS a continuous signal for alarms, pump control and trending.

DCT 531 Industrial Pressure Transmitter with RS485 Modbus RTU
Gauge ranges from 0…100 mbar up to 0…400 bar with an RS485 Modbus RTU interface that supports up to 247 devices on a master-slave network, so several measuring points can share one bus back to the BMS. Stainless steel 316L housing with a welded pressure sensor, and a G 1/2″ flush port option up to 40 bar.

DMP 331 Industrial Pressure Transmitter for Low Pressure
Ranges from 0…100 mbar to 0…60 bar with a 2-wire 4…20 mA output, or 3-wire 0…20 mA or 0…10 V. A stainless steel isolating diaphragm suits non-corrosive liquids and gases, and a G 1/2″ flush port is available from 100 mbar. Intrinsically safe Ex ia and SIL 2 versions are offered where a plant area calls for them.

ATM/T Dual Output Pressure and Temperature Transmitter
Measures pressure and temperature at the same point, saving a second process connection where both readings are wanted. Pressure ranges up to 25 bar with 4…20 mA, 0…20 mA, 0…5 V or 0…10 V outputs and 316L stainless steel or titanium Grade 2 wetted parts. Confirm the temperature range and suitability for your circuit with Stork.

Differential Pressure Across Pumps, Heat Exchangers and Filters

Differential pressure is the signal behind most pump energy savings. Measured across a pump, heat exchanger, strainer or remote index circuit, it lets a variable speed drive hold just enough head for the load and highlights fouling that forces pumps to work harder. On the air side, filter differential pressure shows when loaded filters are adding to fan energy.

DMD 831 Differential Pressure Transmitter with Display and Contact for Fluids and Gases
Differential pressure spans from 0…1 bar up to 0…70 bar for fluids and gases, measured by two piezoresistive stainless steel sensors. A 3-wire 4…20 mA output and rotatable 4-digit LED display showing P+, P- or ΔP, accuracy of ≤ ±1% BFSL and IP65 protection. HVAC filters, fans and pumps and heat exchanger monitoring are among the applications listed for it.

DS 233 Differential Pressure Switch for Gases and Compressed Air in Compact Version
For air filter and fan monitoring, with ranges from 0…6 mbar to 0…1000 mbar for non-aggressive gases and compressed air. One or two PNP switching contacts, a 4…20 mA or 0…10 V analogue output and a configurable 4-digit LED display let it flag filters for replacement once their pressure drop passes a set limit.

Flow and Return Temperature Measurement and Control

The temperature difference between flow and return shows how well a coil, heat exchanger or chiller is being used, and a low delta T often means more water is being pumped than the load needs. Accurate temperature signals let the BMS reset water temperatures and pump speeds to match demand, while a local controller can hold a loop to setpoint where a dedicated control point makes more sense.

SPT-87U Digital Temperature Transmitter
A head-mounted transmitter for a DIN B sensor head that converts RTD or thermocouple inputs into a linear 2-wire 4…20 mA signal. Accuracy is better than 0.5 °C (depending on input type), with galvanic isolation, automatic detection of 2, 3 and 4-wire connections and programmable sensor-break signalling at 3.5 mA or 21.5 mA. Configuration is via the SPT Device Manager software.

PUR-94 D PID Controller with Dual LED Display
A universal input for 0/4…20 mA, 0…10 V, 0…150 mV, RTD or thermocouple signals, with ON-OFF, fuzzy PID and auto-tuning control and dual-loop capability for heating and cooling. The dual LED display shows measured value and setpoint, RS-485 Modbus RTU is standard and the unit is rated IP65.

Logging, Trending and Remote Monitoring

Savings that cannot be measured are hard to defend. Logging pressure and temperature over weeks and seasons reveals plant running out of hours, drifting setpoints and short cycling, and gives a baseline against which improvements can be judged. Where plant is spread across several buildings or sites, remote monitoring brings the data to one place without a site visit.

CMC-99 Multicon Multichannel Controller Data Logger
A touchscreen indicator, controller and data logger with up to 48 inputs from a choice of input and output cards, eight PID control functions as standard and 1.5 GB of internal memory. RS485 Modbus is standard, with optional Ethernet for Modbus TCP/IP and a built-in web server for viewing live data in a browser, and the unit is designed to integrate with PLC, BMS and SCADA systems. Data logging is enabled with a licence key.

SRD-N16 MultiLog Data Logger
A wall-mounted logger with up to eight inputs for thermocouple, RTD and process current or voltage signals, two alarm relays and a graphic LCD for live values and charts. Data is transferred by USB flash drive or over RS-485 Modbus RTU, and the case is rated IP65, making it a practical choice for plant room logging and before and after surveys.

ECHO4 Remote Monitoring System
A self-contained IP67 remote logger with four analogue inputs for 4…20 mA and 0…10 V sensors, optional pulse and RS232/RS485 expansion cards, and two relay outputs for alarms or control. Readings are sent over the cellular network to the ECHOVIEW web platform for graphing, export, reporting and email alarms, which suits outlying plant rooms and buildings without a BMS connection.

Certifications & Compliance

Approvals and protection ratings vary by model and version, so confirm the options you need on the relevant product page or with our team. The products above offer the following:

  • Ex ia intrinsic safety — an intrinsically safe version of the DMP 331 is available for gas and dust environments

  • SIL 2 — the DMP 331 is SIL 2 compliant to IEC 61508 / IEC 61511

  • IP67 ingress protection — the self-contained ECHO4 enclosure

  • IP65 ingress protection — DMD 831, PUR-94 D and the wall-mounted SRD-N16 case