Sensors for Water Quality Management
In a fish farm, hatchery or recirculating aquaculture system, stock health depends on stable water conditions. Temperature drives feeding, growth and oxygen demand, tank and sump levels show whether water is being exchanged as planned, and a change in pump or filter line pressure is often the first sign of a blockage or failing pump. Continuous measurement of these conditions lets operators act before a small drift becomes a mortality event.
Stork Solutions supplies submersible temperature transmitters, submersible level sensors, combined level and temperature probes, pressure transmitters for pump and process lines, and battery-powered loggers and cellular telemetry for remote ponds and tank farms. Housings in 316 stainless steel, marine bronze and Monel alloy are available on selected models, with analogue 4…20 mA and digital SDI-12 outputs to suit your control or monitoring system.
Product Spotlight for Water Quality Management
Why Water Quality Management Matters
Fish and shellfish have little tolerance for sudden change, and many problems in aquaculture and aquatics start with a physical condition that nobody was watching. Continuous data from the water and the plant that treats it allows operators to:
Hold water temperature in range — spot heater, chiller or inflow problems early and keep conditions within the band your species needs
Control tank, pond and sump levels — confirm water exchange, protect pumps from running dry and warn of overflows or leaks
Watch pump and filter line pressure — a rising or falling line pressure can point to a clogged filter, a closed valve or a pump losing performance
Choose materials for the water you have — fresh, brackish and salt water place different demands on housings, so stainless steel, marine bronze and Monel options matter
Monitor remote sites without visits — battery loggers and cellular telemetry bring readings and alarms from outlying ponds and pump houses to a web browser
Sensors for Every Water Quality Management Application
Submersible Water Temperature Monitoring
Temperature is the measurement most closely tied to stock welfare, so probes are often left in tanks, raceways and ponds permanently. Choose the housing material to match fresh, brackish or salt water, and the output to match your controller or logger.
STT-26 Submersible Temperature Transmitter
A PT100 class B sensor with a 2-wire 4…20 mA output, powered from 10 to 30 V DC, with the range user-programmable via the USB Config MKII. Housings are 316 stainless steel (STT-26-SP), CA104 marine bronze for seawater (STT-26-MT) or Monel alloy 400 for deep seawater and corrosive environments (STT-26-NT). IP68 rated, with PUR or TPE-U submersible cable depending on version.
STT-28 SDI-12 Submersible Temperature Transmitter
A low-power NTC thermistor probe with SDI-12 output, available in stainless steel or marine bronze and as a standard probe or a 10 mm thin-walled probe for faster response. Fully submersible to IP68, it suits harbour seawater monitoring, marine biology studies and battery or solar-powered logging stations.
Tank, Pond and Sump Level
Hydrostatic level sensors hang in the water and report depth continuously, giving a reliable picture of tank volumes, pond levels, sump levels in RAS plant and flow over weirs. For use in brackish water or seawater, confirm suitability with Stork.
SLS-SA Submersible Level Sensor, Analogue Output
Level ranges from 0.5 mWG up to 100 mWG with accuracy options down to <±0.1%. Outputs include 4…20 mA (2-wire), 0…5 V or 0…10 V (3-wire), 0.5 to 4.5 V ratiometric and a low-power millivolt signal, with an optional temperature output. The 316 stainless steel sensor has an isolated diaphragm, FKM, EPDM or NBR seal options and PUR submersible cable, and is IP68 rated for submersion to 100 m.
SLS-SD Submersible Level Sensor, Digital Output
An SDI-12 v1.4 sensor that outputs both level and temperature as standard, over a range of about 0.5 to 100 mWG. Up to 9 sensors can share one bus, and current draw is under 250 µA idle and under 4 mA active, which suits battery and solar-powered stations. 316 stainless steel housing, PUR cable and IP68 protection to 100 m depth.
Level and Temperature from a Single Probe
Where both depth and water temperature are needed at the same point, one combined probe reduces the number of cables, mountings and inputs. This is useful in holding tanks, header tanks and water storage feeding a farm or hatchery.
LMK 307 T Level and Temperature Transmitter
Level ranges from 0…4 mH₂O up to 0…250 mH₂O and temperature ranges from 0…30 °C up to 0…70 °C, each on its own 2-wire 4…20 mA output. The compact 26.5 mm stainless steel probe uses a flush ceramic sensor, with options for different cables, elastomers and customer-specific adaptations.
Pump Line Pressure, Logging and Remote Telemetry
Pumps, filters and pipework keep water moving through the system, and pressure readings on those lines show how well they are performing. Loggers and telemetry then collect pressure, level and temperature signals from sites that are hard to wire back to a central control room.
26.600 G OEM Pressure Transmitter Standard
Nominal ranges from 0…1 bar to 0…400 bar with accuracy of ≤±0.5% FSO and a standard 2-wire 4…20 mA output (3-wire options available). A stainless steel 1.4301 (304) port and housing, 96% Al₂O₃ ceramic diaphragm and FKM seals, with a response time of ≤10 ms, suit pump and process line monitoring in water treatment.
Triton Series Data Logger
A battery-powered logger for pressure and flow, with internal or external pressure sensing from 1 bar to 400 bar (40 bar maximum internal), 0/4…20 mA, 0.5 to 4.5 V and 0…5 V or 0…10 V inputs, and pulse inputs up to 400 pulses per second. Battery life is greater than 5 years at 15-minute intervals, and the IP68 housing is submersible to 10 m. Applications include pump on/off timing, leakage and flow monitoring and reservoir monitoring.
ECHO4 Remote Monitoring System
A cellular telemetry unit with 4 analogue inputs, 5 pulse inputs (with expansion card), RS232 and RS485 serial interfaces and 2 relay outputs for alarming or control, in an IP67 self-contained enclosure. Data is sent over a multi-network SIM to the ECHOVIEW web platform, with alarms by portal or email, for pumping station, utility and farming monitoring.
Certifications & Compliance
Approvals and protection ratings vary by model and version, so confirm the options you need on the relevant product page or with our team. The products above offer the following:
IP68 ingress protection — STT-26, STT-28, SLS-SA and SLS-SD for continuous submersion, and the Triton Series Data Logger, submersible to 10 m
IP67 enclosure — ECHO4 Remote Monitoring System, in a self-contained IP67 rated enclosure
WRAS-approved granules — used in the PUR cable of the STT-26-SP for drinking water applications
SDI-12 v1.4 compliance — SLS-SD, fully verified and compliant with the SDI-12 v1.4 standard
IEC 60770 accuracy reference — 26.600 G OEM Pressure Transmitter Standard