Level and Pressure Transmitters for Aquaculture Pump Control
In a fish farm or recirculating aquaculture system (RAS), the pumps are the life-support system. Recirculation, supply and drain pumps keep water moving through tanks, biofilters and treatment stages, while aeration and oxygenation equipment holds dissolved oxygen where the stock needs it. A pump that runs dry, works against a closed valve or keeps going while a filter blinds can damage water quality within minutes, so control decisions need dependable level and pressure signals from sumps, tanks and pipework.
Stork Solutions supplies submersible level transmitters for sump and tank level, pressure transmitters and electronic pressure switches for pump discharge and line pressure, and differential pressure transmitters for filter monitoring. Outputs include 4…20 mA, 0…10 V, switching contacts and RS485 Modbus RTU, so each measurement can drive local pump logic and also feed alarms, telemetry and SCADA.
Product Spotlight for Aquaculture Pump Control
Why Aquaculture Pump Control Matters
Pump faults in aquaculture rarely stay small: a stopped recirculation pump or an empty sump affects every tank on the loop. As part of a wider aquaculture and aquatics instrumentation strategy, continuous level and pressure measurement allows operators to:
Set pump start and stop points — hold sump and tank level within a defined band so duty and standby pumps start only when they are needed
Protect pumps from dry running — a falling sump level or loss of suction pressure can stop a pump before it runs dry and damages seals or impellers
Confirm pumps are delivering — discharge and line pressure show whether supply and recirculation pumps are actually moving water, not just drawing current
Catch filter blinding early — rising differential pressure across drum, bead, sand or cartridge filters signals the need to backwash or clean before flow drops
Raise alarms remotely — analogue, switching and Modbus outputs feed PLCs, telemetry and SCADA so out-of-hours staff hear about a fault straight away
Level and Pressure Transmitters for Every Aquaculture Pump Control Application
Sump and Tank Level for Pump Start/Stop and Dry-Run Protection
A submersible hydrostatic probe in the pump sump or tank gives a continuous level signal, so start, stop and low-level cut-out points can be set and adjusted in the controller rather than relying on a float alone.
LMP 307 Stainless Steel Level Transmitter
Ranges from 0…1 mH₂O to 0…250 mH₂O with a 2-wire 4…20 mA or 3-wire 0…20 mA / 0…10 V output. The 26.5 mm stainless steel probe is designed for water and clean fluids, with stated applications including pump and booster stations, containers and water recycling. Optional DVGW and KTW drinking water certificates, SIL 2 and an Ex ia version are available.
LMK 458 Level Transmitter for Marine and Offshore
Ranges from 0…40 cmH₂O to 0…200 mH₂O with a 2-wire 4…20 mA output. A capacitive ceramic sensor with a 99.9% Al₂O₃ diaphragm sits in a 39.5 mm housing offered in stainless steel or CuNiFe. Designed for marine and offshore conditions, with desalination among its stated applications, it is a candidate for brackish and seawater systems; confirm suitability for your water with Stork.
LMK 807 Plastic Level Transmitter for Aggressive Media
Ranges from 0…4 mH₂O to 0…100 mH₂O with a 2-wire 4…20 mA output. The 35 mm plastic probe has a flush-mounted ceramic sensor that solid deposits slide off during cleaning, so it is worth considering for drain sumps and backwash or sludge collection where solids build up. An optional SIL 2 version is available; confirm seawater suitability with Stork.
Pump Discharge and Line Pressure
Pressure on the discharge side confirms that a pump is delivering and lets the control system detect a closed valve, blocked line or burst pipe. On the suction side, a low-pressure trip adds a second layer of dry-run protection.
DMK 331 Industrial Pressure Transmitter
Ranges from 0…400 mbar to 0…600 bar with a 2-wire 4…20 mA or 3-wire 0…20 mA / 0…10 V output. A ceramic sensor with a G 1/2″ flush port for polluted media, or a PVDF open port for aggressive media, suits pump and water treatment duty. An optional oxygen application version is listed, which may be relevant on oxygenation lines (confirm your application with Stork), and Ex ia and SIL 2 versions are also available.
DS 200 Electronic Pressure Switch
Ranges from 0…100 mbar to 0…600 bar, with 1, 2 or 4 configurable PNP switching contacts and a 4…20 mA or 0…10 V analogue output. The rotatable 4-digit LED display shows pressure at the pump, and the contacts can trip a pump on low pressure or raise a high-pressure alarm directly. Pumps and water engineering are among its stated applications, and an Ex ia version is available.
Differential Pressure Across Filters
Mechanical and biological filtration in a RAS loop gradually loads with solids. Measuring the pressure drop across a drum, bead, sand or cartridge filter shows when it needs backwashing and warns of blockage before recirculation flow falls.
DMD 331 Differential Pressure Transmitter for Liquids and Gases
Differential ranges from 0…20 mbar to 0…16 bar, with one-sided static pressure up to 30 times the range and a 2-wire 4…20 mA or 3-wire 0…10 V output. It handles wet/wet measurement on liquids, and filter condition monitoring, pump controls and pumping stations are among its stated applications. The piezoresistive stainless steel sensor is 316L compatible, and an Ex ia version is available.
DMD 831 Differential Pressure Transmitter with Display and Contact for Fluids and Gases
Differential ranges from 0…1 bar to 0…70 bar with a 3-wire 4…20 mA output, a switching contact and a 4-digit LED display that can show P+, P- or ΔP. Accuracy is within ±1% BFSL, the stainless steel 316L pressure port is rotatable and the unit is rated IP65, giving operators a local reading at the filter as well as a backwash or alarm signal.
Telemetry, Alarms and Digital Integration
Larger farms and hatcheries often run many pumps across several buildings or sites. A digital bus cuts wiring and lets one controller read every pressure point, while the analogue and switching outputs of the products above connect directly to existing PLCs, alarm diallers and telemetry outstations.
DCT 531 Industrial Pressure Transmitter with RS485 Modbus RTU
Ranges from 0…100 mbar to 0…400 bar with an RS485 Modbus RTU interface supporting up to 247 slaves on one network. Stainless steel 316L construction, a G 1/2″ flush port option up to 40 bar and a reset function suit multi-point pump pressure monitoring fed into SCADA. Confirm seawater suitability with Stork.
Certifications & Compliance
Approvals and protection ratings vary by model and version, so confirm the options you need on the relevant product page or with our team. The products above offer the following:
Ex ia intrinsic safety — optional on the LMP 307, LMK 458, DMK 331, DS 200 and DMD 331
SIL 2 functional safety — optional on the LMP 307, LMK 807 and DMK 331 (IEC 61508 / IEC 61511)
DVGW and KTW drinking water certificates — optional on the LMP 307
Marine approvals — Lloyd’s Register, DNV, ABS and CCS on the LMK 458
IP65 ingress protection — DMD 831