Home / Company News / BSP vs NPT Threads: What Is the Difference?
BSP vs NPT Threads: What Is the Difference?
When replacing a pressure sensor, transmitter, gauge or fitting, the thread connection is often treated as a small detail. In reality, it is a critical part of the specification.
A pressure transmitter may have the correct pressure range, electrical output and material compatibility, but it cannot be installed safely or reliably if its process connection does not match the existing port. One of the most common questions is whether BSP and NPT threads are the same — or whether they can be used together.
The simple answer is no: BSP and NPT threads are different thread standards and should not be assumed to be interchangeable.
Although some BSP and NPT connections can look similar, their thread geometry, pitch, angle and sealing methods differ. Attempting to force an incorrect thread into a port can cause leaks, damage the fitting or sensor, and create avoidable downtime.
This guide explains the difference between BSP and NPT threads, how to identify them and what to check before ordering a replacement pressure device.
What do BSP and NPT stand for?
BSP stands for British Standard Pipe. It is a family of pipe thread standards commonly encountered in the UK, Europe and many international industrial applications.
NPT stands for National Pipe Thread. It is a tapered pipe thread standard commonly used in North American equipment and applications.
Both are used to connect components that carry liquids or gases, including pipes, valves, manifolds, pressure gauges and pressure transmitters. However, their design is not the same.
Before selecting a replacement device, it is important to identify not only the nominal thread size, such as 1/4 inch or 1/2 inch, but also the thread standard and whether the connection is parallel or tapered.
Is a G thread the same as BSP?
A thread marked with a G designation, such as G1/4 or G1/2, is a BSP parallel thread. It is also commonly called BSPP, meaning British Standard Pipe Parallel.
The “G” does not indicate the physical outside diameter of the thread. Instead, it identifies a nominal pipe thread size. For example, G1/4 refers to a standardised BSP parallel thread, not a thread with a 1/4-inch outside diameter.
For a more detailed explanation, see Stork Solutions’ guide: What does the “G” stand for in G1/4 or G1/2 thread?
This distinction matters because a G thread is parallel, while NPT is tapered. Even where the nominal sizes appear similar, the connections use different thread forms.
What is the difference between BSPP, BSPT and NPT?
There are two main BSP thread types that engineers and maintenance teams commonly encounter:
- BSPP — British Standard Pipe Parallel
- BSPT — British Standard Pipe Taper
NPT is also tapered, but it is not the same as BSPT.
Thread type | Thread form | Typical sealing approach | Key point |
BSPP / G | Parallel | Seal at a face, shoulder, washer, bonded seal or O-ring arrangement | The thread itself does not usually provide the seal |
BSPT / R | Tapered | Thread engagement with an appropriate sealing method | Uses BSP thread geometry |
NPT | Tapered | Thread engagement with thread sealant | Uses a different thread geometry from BSPT |
BSPP or G threads
BSPP threads have a constant diameter along the threaded length. They are generally used with a sealing arrangement outside the thread itself, such as an O-ring, gasket, bonded seal or sealing face.
This is why it is important to consider the complete connection design, not just the thread. A parallel thread without the correct sealing arrangement may screw into place but still leak.
Where a device uses a parallel DIN 3852 connection, suitable sealing methods should be confirmed before installation. We also cover this topic in our guide to recommended sealing methods for parallel DIN 3852 threads.
BSPT or R threads
BSPT threads are tapered. The diameter changes along the threaded section, producing a progressively tighter fit as the male and female components are assembled.
Although BSPT and NPT are both tapered threads, they remain different standards. A tapered profile alone does not make two thread types compatible.
NPT threads
NPT is also designed as a tapered thread. The taper helps create a tight mechanical connection as the fitting is screwed in, but the joint normally requires suitable thread sealant to reduce the risk of leakage through the thread path.
For NPT pressure transmitter connections, Stork Solutions recommends thread sealant tape or liquid thread sealant rather than relying on the metal-to-metal connection alone. Read more in the guide: Do pressure transmitters with NPT threads require thread seal tape?
Why are BSP and NPT threads not interchangeable?
BSP and NPT threads can appear close enough to fit at first, especially in smaller nominal sizes. However, they have important geometric differences.
The key differences include:
- Thread angle
BSP threads use a 55-degree thread angle, while NPT threads use a 60-degree thread angle. - Thread profile
The form of the thread crests and roots differs between the standards. - Thread pitch
Some nominal sizes have different threads per inch. For example, a 1/4-inch BSP thread and a 1/4-inch NPT thread do not use the same pitch. - Taper and sealing method
BSPP is parallel and normally seals using a separate sealing arrangement. NPT is tapered and normally uses sealant on the threads.
These differences mean that even if a connection starts to engage, it may not provide the correct mechanical fit or seal. Forcing a mismatched fitting risks damaging both the sensor connection and the mating port.
What can happen if the wrong thread is fitted?
Using an unsuitable thread connection can create problems immediately or over time. Common issues include:
- Leakage from the connection
- Damaged threads in the port or fitting
- Incomplete mechanical engagement
- Difficulty removing the device later
- Stress on the sensor housing or process connection
- Loss of pressure measurement due to an unsuitable installation
- Unplanned maintenance or machine downtime
In pressure measurement applications, a reliable process connection is just as important as selecting an appropriate pressure range, output signal and accuracy specification. Stork Solutions’ pressure measurement range includes pressure sensors, transducers, transmitters, gauges, switches, data loggers and calibration equipment, all of which require the correct connection to suit the application.
How can you identify whether a thread is BSP or NPT?
The most reliable approach is to check the existing component specification or original equipment documentation. If that information is unavailable, the thread should be measured and assessed carefully before ordering a replacement.
Check the marking or part number
Look for markings such as:
- G1/4 or G1/2 — normally BSPP / parallel
- R1/4 or R1/2 — normally BSPT / tapered
- 1/4 NPT or 1/2 NPT — NPT tapered thread
Do not rely on the nominal size alone. A device described simply as “quarter-inch thread” does not provide enough information to identify the correct standard.
Measure the thread diameter
Use callipers to measure the outside diameter of a male thread. This can help narrow down the likely thread family and nominal size.
However, diameter alone is not enough. Some thread sizes appear very similar in diameter despite using different thread angles or pitches.
Check whether the thread is parallel or tapered
Measure the outside diameter at more than one point along the male thread:
- If the diameter remains consistent, it is likely parallel.
- If the diameter changes along the thread length, it is likely tapered.
This does not confirm whether the thread is BSPT or NPT, but it is a useful first check.
Check thread pitch
A thread pitch gauge is the most practical way to compare the spacing of the threads. Correctly identifying the pitch helps distinguish between thread standards that may otherwise look alike.
If there is any uncertainty, provide the original part number, photographs, measured dimensions and application details when requesting support. This enables the complete pressure transmitter requirement to be assessed rather than selecting a connection based on appearance alone.
Selecting the right pressure device connection
The process connection is only one part of a pressure measurement specification. When replacing or selecting a sensor, also consider:
- Pressure range, including normal operating conditions and possible peaks
- Gauge, absolute or differential pressure reference
- Process medium and material compatibility
- Process temperature and ambient conditions
- Electrical output and supply requirements
- Cable, connector and enclosure requirements
- Space constraints and mounting orientation
- Required sealing method
- Installation torque and service access
For example, an application may require a specific sensor material for the process medium alongside either a G1/4 or 1/4 NPT connection. Stork Solutions has previously supplied a pressure-sensor option for chlorinated and saltwater applications with both G1/4 male and 1/4 NPT thread options. This illustrates why the thread must be specified clearly when discussing a replacement.
Get the connection right before installation
BSP and NPT threads should not be treated as interchangeable. BSP may be parallel or tapered, while NPT is a distinct tapered thread standard with its own geometry and sealing requirements.
Before fitting a new sensor, gauge or transmitter, confirm:
- The thread standard
- The nominal thread size
- Whether the thread is parallel or tapered
- The required sealing method
- The pressure, medium and environmental requirements of the application
Taking these checks before ordering helps avoid leaks, damaged ports and unnecessary installation delays.
Sam Drury
On this page
- What do BSP and NPT stand for?
- Is a G thread the same as BSP?
- What is the difference between BSPP, BSPT and NPT?
- BSPP or G threads
- BSPT or R threads
- NPT threads
- Why are BSP and NPT threads not interchangeable?
- What can happen if the wrong thread is fitted?
- How can you identify whether a thread is BSP or NPT?
- Selecting the right pressure device connection
- Get the connection right before installation
Share
More from the blog

Choosing a Pressure Transmitter for Low-Pressure Biogas Applications
Biogas digesters typically operate at only a few millibars of pressure, so choosing a low-pressure biogas pressure transmitter means getting accurate measurement at a very

Why Is My Pressure Transmitter Reading a Negative Value?
A negative pressure reading is not automatically a fault. In some applications, it is the correct measurement. In others, however, it can point to an

BSP vs NPT Threads: What Is the Difference?
When replacing a pressure sensor, transmitter, gauge or fitting, the thread connection is often treated as a small detail. In reality, it is a critical

Standard vs Bespoke Sensors: OEM Selection Guide
For Original Equipment Manufacturers (OEMs), machine builders and product design engineers, selecting the right sensor package is a critical engineering decision. Instrumentation provides the fundamental

Replacing Legacy Industrial Sensors: What to Consider
Industrial sensors provide the measurement data needed to run equipment safely, consistently and efficiently. Whether they measure pressure, level, temperature or another process variable, these

Analogue vs. Digital Level Sensors: Which to Choose?
When specifying a level sensor, one of the first decisions you’ll face is output type: analogue or digital? Both do the same fundamental job —